Cooling tower water treatment

We keep your cooling towers clean, efficient and under the EMSD Legionella limits — and give you the records to prove it.

THE SHORT ANSWER

A cooling tower treatment programme does three jobs at once: it stops scale forming on heat-transfer surfaces, it protects metal from corrosion, and it controls bacteria including Legionella. Gotech designs the programme around your water and your metallurgy, doses and tests it on a set schedule, and documents every visit for your compliance file. We have run these programmes in Hong Kong since 1982.

A cooling tower is warm, wet and open to the air. It is also, by design, an evaporative device — which means every litre that evaporates leaves its dissolved minerals behind in the system. Scale concentrates, dirt blows in, and bacteria find a warm nutrient-rich home. Left alone, this raises your energy bills, eats your plant, and can trigger an EMSD notice.

The three problems are not independent. Push pH down to stop scale and you accelerate corrosion. Push it up to protect metal and you precipitate scale — and you also cripple your chlorine, because chlorine loses most of its killing power above pH 8. A programme is the act of balancing all three at once, continuously, on your specific water.

What the programme covers

  • Scale control — inhibitors that hold minerals in solution so they cannot deposit on hot surfaces
  • Corrosion control — film-forming inhibitors that protect the metal, maintained at a residual rather than dosed once
  • Biological control — biocide dosing matched to your actual operating pH, not a generic recipe
  • Cycles and blowdown — controlling how far the water concentrates before it is bled off
  • Routine testing — pH, conductivity, inhibitor residual, chlorine and Legionella
  • Cleaning and disinfection on a schedule set by the tower's condition and risk
  • A dated report after every visit — the paper trail for your compliance file

What happens on site

  1. Survey. We look at the tower, the basin, the fill, the drift eliminators and the dosing equipment, and we test the make-up water. The programme is designed from what we find, not from a catalogue.
  2. Set the programme. Chemistry chosen for your water, your metals and your operating pH. Dosing equipment set up and calibrated.
  3. Service visits. Our technician tests on site, adjusts the dose, checks the equipment is actually feeding, and records the readings.
  4. Laboratory testing. Periodic samples including Legionella, analysed and reported formally.
  5. Scheduled cleaning. Cleaning, desludging and disinfection at the frequency the tower's condition and risk require.
  6. Report. A dated written report after every visit — what was tested, what it read, what was done.

Why it matters

Hiring a contractor does not remove the building owner's legal responsibility for a cooling tower. If the work is not done properly, or the records are not there to show it was, the exposure stays with you. What protects an owner is two things together: treatment that keeps the water safe, and documents that prove it.

What it costs to get this wrong

The bill for poor treatment is not one number in one year — it arrives continuously. Just 1/32 of an inch of scale can cut heat-exchange effectiveness by over 10%, which on a large chiller is real money every month. Corrosion, meanwhile, does not add a cost so much as drag one forward, shortening plant life and pulling a capital replacement years closer. And a Legionella count at or above 1,000 cfu/mL brings a statutory notice and emergency decontamination. We modelled all of this properly in the real cost of doing nothing — including the case where treatment does not pay.

Common questions

How often do you visit?

It depends on the tower's size, duty and risk. A typical commercial tower is serviced monthly, with laboratory testing at a set frequency and cleaning scheduled separately. We set the interval from the survey rather than selling a fixed package, and we will tell you if you are being over-serviced.

Can you take over a tower another contractor treats?

Yes, and it is common. We start with an independent survey and water test so you get a clear picture of the condition you are inheriting. If you want that assessment before switching, that is an independent audit.

Why does my chlorine residual look fine but the Legionella count is high?

Usually pH. Chlorine forms hypochlorous acid, which dissociates to a far weaker form as pH rises — at pH 9 roughly 95% of your free chlorine is in the weak form. The test still reads a residual; the kill is not there. This is one of the most common failures we see, and we cover the chemistry in effects of pH on various biocides.

Do you supply the chemicals as well as the service?

Yes. Gotech has supplied water treatment chemicals in Hong Kong since 1982 and we supply what we dose, matched to your system rather than sold off a shelf.

How much does cooling tower water treatment cost in Hong Kong?

It depends on the tower's size, duty and condition, so there is no list price. Every job starts with a free site visit and assessment: we survey the system, test the water, and send a written quotation for your records that lists each job.

Every job includes

  • A free site visit and assessment
  • A written quotation for your records
  • A dated report after every visit
  • Work that follows the EMSD Code of Practice